| Nikon Eclipse i-Series 80i with camera: QICAM 12-bit Mono Fast 1394 Cooled |
 |
 |
|
Main Features of Nikon Eclipse i-Series 80i
Optimal digital imaging optics
– Built-in “fly-eye” optics to ensure uniform illumination.
– Chromatic aberration in the newly developed Plan Apo VC objectives has been corrected even further to achieve flat, high-resolution images, right to the edge.
– A newly developed Digital Imaging Head integrates a binocular unit, fluorescence illuminator, dual port and zoom optics into one single unit, making it perfect for digital imaging and fluorescence microscopy.
•Automatic detection of microscopy status
– When the Nikon DS-5M-L1 digital camera is mounted on the digital-imaging head, imaging data such as the objective magnification and fluorescence filter selection are automatically detected and can be displayed on the monitor. These data can be saved with the image file when the image is captured with the camera.
Upgraded DIC performance
– Both optimum contrast and high resolution have been achieved at the best balance, while minimizing uneven color. Three types of DIC prisms—high-resolution, high-contrast, and standard—are available.
Enhanced fluorescence performance
– The fluorescence illuminator employs Nikon’s unique Noise Terminator mechanism. It directs stray light out of the objective light-collection path, minimizes noise and dramatically improves signal-to-noise (S/N) ratios.
– An optional Excitation Balancer can freely adjust excitation wavelengths. During observations or imaging of multi-stained specimens, the operator can easily emphasize the specific wavelength of the excitation light without changing the filter cubes. The excitation wavelength’s spectral intensity of the multi-band filter can be changed continuously by adjusting the sliding distance of the Excitation Balancer into the optical path. |
QICAM 12-bit Mono Fast 1394 Cooled
For quantitative analysis in brightfield imaging in life science and industrial applications |
Features
- 1392 x 1040 pixels
- 4.65µm x 4.65µm pixel size
- 1/2" optical format
- Electronic shutter
- 12-bit
- Binning up to 8x8
- ROI
- External trigger
|
Applications
- Brightfield/Dark Field Microscopy
- Live Cell Imaging
- Pathology, Histology, Cytology
- DNA Analysis
- Motility and Motion Analysis
- Semiconductor Inspection
- Failure Analysis
- Forensic Analysis
|
|
| |
|
|
| Spectrophotometer |
|
|
 |
DU® 800 UV/Visible Spectrophotometer
The DU 800 Spectrophotometer is a PC controlled system intended for use in quantitative and qualitative analysis in biological and industrial procedures that require spectrophotometric measurements in the UV and visible region of the electromagnetic spectrum. It operates in the wavelength range of 190 to 1100 nm and has a bandwidth of <= 1.8 nm. The focused micro-beam design provides a wide linear range and other specific benefits for small volumes and precious samples. The control of the instrument, data handling, and data reduction capabilities are contained within the confines of the PC. The frame-oriented software provides a convenient and user-friendly interface and, therefore, ensures a quick learning curve. |
Standard Software
The following applications are avilable with the software installation.
-
Fixed Wavelength - Performs Absorbance or %Transmittance readings for up to 12 wavelengths simultaneously. A factor or custom formula may be applied to calculate final results.
-
Wavelength Scan - Performs wavelength scans in Absorbance or %Transmittance. Acquired scan data are stored and may be used for various manipulations and calculations. Includes the calculation mode to add, subtract, multiply and divide spectra.
-
Kinetics/Time - Simultaneously measures and analyses up to 12 rate reactions. Data can be reviewed in real time and automatically calculated and printed. The rate of the kinetic reaction is reported using a linear regression.
-
Nucleic Acid Analysis - Determines protein impurity in nucleic acid samples based upon the ratio of readings at two wavelengths with a choice of background correction. Protein and nucleic acid concentrations can also be calculated using the Warburg and Christian1 coefficients.
-
Single Component Analysis - Determines the concentration of unknowns by either linear or non-linear (quadratic) regression and provides statistical analysis for the standard curve. The standard curve can have up to 30 standards. The operator can re-run any standard, remove or add standards, and have the instrument re-calculate the curve.
-
Performance Validation - Provides a simple procedure to verify the performance of the instrument without standards or samples. Tests include: wavelength accuracy and repeatability, resolution, baseline flatness, noise, and stability.
In addition, the "rapid" modes RediRead™ and RediScan™ are available. These provide the user with a fast and easy way to take readings at fixed wavelengths or to make wavelength scans. |
| |
|
|
 |
ORCA® Robot
Compact, yet robust, the ORCA® Robotic Arm brings dependable robotic automation to the laboratory with precision and flexibility. ORCA® (Optimized Robot for Chemical Analysis) works reliably with common labware and instrumentation in a space-efficient, time-saving and safe manner. The ORCA® Robotic Arm is a key component of the SAGIAN™ Core System Strate.
|
The Robotics Advantage
- Increase productivity by running unattended 24 hours a day, freeing lab personnel for other valuable tasks.
- Improve repeatability by minimizing variability between operators.
- Increase safety of laboratory personnel by minimizing repetitive motions and reducing exposure to chemicals and biohazards.
- Simplify implementation of standardized procedures and methods.
- Improve documentation required for validation.
|
Reliable Automation
- Drug discovery
- Genetic analysis
- Sample preparation
- Quality control / assurance, and
- Clinical testing
|
| |
|
|
| Biomek® FX Laboratory Automation Workstation |
|
 |
|
|
| Biomek FX |
Span-8 pipetting |
Multipod pipetting |
- Multichannel (multipod) pipetting for rapid compound transfers and reagent addition
- Eight-channel (Span-8) independent axis pipetting for adding controls and performing dilutions
- Precise, rapid plate-to-plate liquid transfers and reagent addition
|
Applications
- Plate Replication: four formattling options 96-96, 96-384, 384-96, 384-384
- Primary Screening
- Secondary Screening
- Plasmid Purification using vacuum filtration
- Plasmid Purification using magnetic beads
- PCR* Reaction Setup
- PCR* Reaction Cleanup
- Sequencing Reaction Setup
- Dye Terminator Removal
- Genomic DNA purification from blood
|
| |
|
|
| |
|
|
| Flow Cytometer |
|
|
 |
COULTER® EPICS® XL-MCL™ Flow Cytometer
This unique system redefines the standards of flow-cytometric analysis. The flow cytometer combines the analytical power of a research cytometer into a compact, truly walk away, clinical analyzer ergonomically designed to expedite sample throughput.
|
The XL system features the capability to analyze up to 4 colors of immunofluorescence from a single air cooled laser. Other multi-color applications include: multiparametric DNA analysis, platelet studies, reticulocyte enumeration, cell biology/functional studies and as well as a broad range of research applications. The instrument is self contained and biohazard safe. The user retains the flexibility to change filter elements for versatility in research settings.
For high volume users, the XL-MCL system offers walk away sample handling for superior efficiency with the Multi Carousel Loader (MCL). Capable of throughputs of up to 100 samples per hour, the fully featured XL-MCL incorporates positive bar-code identification and true vortex mixing prior to aspiration.
The XL remains the only flow cytometer to offer state-of-the-art Digital Signal Processing (DSP) for reliable linearity and drift-free amplification and compensation. The single laser design eliminates concerns regarding multi-beam stability, signal delay and alignment. Compensation is achieved by a unique digital compensation matrix. |
| |
|
|
| Centrifuges: |
|
|
 |
Allegra 25R Refrigerated Benchtop Centrifuge - Hands-free operation with automatic door latch - "Cadillac Close"
- Magnetic rotor ID for precise performance
- Extremely quiet, maintenance-free brushless induction drive
- Operating temperature - from 2º C to 40º C to protect integrity of samples
- Interchangeable rotors accommodate "Cells to Wells" from 0.25 to 500 mL
|
 |
Optima™ MAX Series Personal Benchtop Ultracentrifuge
(1,019,000 x g; 130,000 rpm)
- Operating temperature - from 0º C to 40º C to protect integrity of samples
- Capable of handling volumes from just a few µL up to 64 mL, applications range from simple pelleting to differential gradient separations, including:
- Proteins
- DNA and RNA
- Subcellular fractions
- Membranes
- Viruses Lipoproteins
|
| Balances: |
|
|
|
|
|
Scout Pro SP202
with precisions 200g x 0.01g,
400g x 0.01g, 400g x 0.1g |
Mettler Toledo AX 205
with capacity 220g & precision 0.01mg |
Mettler Toledo UMX2
with capacity 2.1g & precision 0.1µg |
| |
|
Microplate Readers
 |
Synergy™ HT Multi-Detection Microplate Reader
The Synergy™ HT utilizes a unique “dual-optics” design combined with monochromator wavelength selection to provide uncompromised performance in absorbance, fluorescence and luminescence reading modes.
|
Features
- Automatic top and bottom epifluorescence read modes optimized for both sensitive homogeneous and cell-based assays
- Software-controlled automatic probe height adjustment with built-in plate sensor to prevent probe crashes
- Scanning monochromator for wavelength scans to identify peak absorbance and provide full spectral analysis
- Luminescence measurements with top detection for best sensitivity
- Reads 6- to 384-well plate formats including PCR trays and Terasaki plates
- Well area scanning for popular cell-based assays
- Time Resolved Fluorescence capability
- Dual Reagent Dispensers
- USB and serial ports for easy connectivity
|
 |
BMG Fluorostar Optima is a fully automated microplate based multi-detection reader designed for life science laboratories in academia and industry. The FLUOstar incorporates four different measurement principles:
• Fluorescence Intensity - including FRET and multilable applications
• Time-Resolved Fluorescence - including DELFIA™
• High-Performance Luminescence (flash and glow) - dedicated luminescence circuit
• Absorbance - UV/Vis with 1 cm path length correction |
| |
|
|